ZLG-CAN Tool User Guide
Compatible with Mainstream CANTest Software
Installation Steps
1. After downloading CANTest_Setup_V2.68, run CANTest_Setup.exe to start the installation.
2. Change the name of the file in CANTest installation directory from "ControlCAN.dll" to
"ControlCAN.dll.bak", as a backup.
3. Copy "ControlCAN.dll" file to CANTest installation directory.
At this point, you have completed the software installation process.
4. Open and run CANTest.exe, after the correct installation of USB-CAN adapter\CANalyst-II analyzer driver of our company, the operation can be performed by CANTest software.
5. If you need back to use mainstream USB-CAN-B, you can change the backup file "ControlCAN.dll.bak" to "ControlCAN.dll" and cover to replace the existing file with the same name.
Compatibility Manual
Using our USB-CAN TOOL software can play the best performance of the equipment), when you use mainstream CANTest software to operate our USB-CAN-B, there may be a few functions that can hardly be used cannot compatible with mainstream CANTest software temporarily, but will not affect the use of normal functions.
When using mainstream CANTest Software to operate our USB-CAN-B, Compatible part includes: Baud rate setting, Filter settings (partially compatible), Standard Frame \Extern Frame \ Remote Frame \ Data Frame transmission and reception, and so on.
Those temporary incompatible functions include:
1. When starting the software, in the "Select Device" dialog box, select the baud rate (The baud rate under 10kbps does not support)
when starting up mainstream CANTest software, the "Select Device" dialog box filled in the initial parameters will pop up, which has a drop-down list of baud rates, including 10 kinds of common baud rates ranging from 5kbps to 1000kbps and others, As shown in the figure below:
Our USB-CAN-B does not support the baud rate under 10kbps, so the list 5kbps baud rate parameter is invalid:
Note: if you carry on secondary development based on our USB-CAN-B, for the use of the interface function as well as the compatibility of the mainstream function library, please refer to Bus Interface Adapter Interface Function Library User Manual.
How to compatible with CANPro Protocol Analysis
The purpose of this document is to guide our clients on the first time buying and using the CANalyst-II analyzer to be compatible with PC software of CANalyst-II analyzer, namely CANPro Protocol Analysis Software.
How to Compatible with CANPro Software
1. After downloading CANPro_Setup1.50.2.367, unzip and install CANPro_Setup1.50.2.367.exe first, and then install three protocol analysis plug-in installation packages.
2. Copy "ControlCAN.dll" and "cantype.ini" files to CANPro installation directory, Overwrite file with the same name.
At this point, you have completed the software installation process.
3. Open and run CANPro.exe, after the correct installation of the USB-CAN-B driver, the operation can be performed by CANPro software.